symptom
|
Possible problems and solutions
|
Normal key, not the reader;
Beep sound when opened eight lockout ...
|
Lack of direct current, controller failure;
It is necessary to increase a DC power supply to the electric lock power supply or replace
Reset the card after the effective power increase
|
Key Normal,
Reading distance near or insensitive reader
|
1. The controller placed on a metal surface;
Adjust the position of Controller
2. Current supply shortage;
Adjust Power
|
After the reader toot, toot, do not unlock
|
1 . Set up Card + PIN mode;
Enter the password to open the door or adjustment
2 . Before the reader is pressed [ # ] key;
Wait 5 seconds later to reader
|
Valid card beep does not unlock
|
Magnetic detection is provided unlocked state, then there is no door sensor or the door is not closed;
Magnetic detection of the closed state or the unlocked closed door sensor
|
[*] + [ Programming password ] halfway beep sounding, did not enter the programming mode
|
Press [*] before button, press the other keys;
Press and hold the [* ] key press after a long beep [*] + [ programming password ] to
|
[ # ] Key, beep, can not modify the personal password
|
Press [ # ] before button, press the other keys;
Press and hold the [ # ] key, appears a long beep, press [ # ] to
|
Press [5] , 3 beeps
|
The controller card capacity is full
|
[5] + [ encoding ] , toot toot
|
This encoding has been used;
To be re [5] + [3 -bit code ] Operation
|
[5] + [ encoding ] beeps + [ induction card ] toot toot
|
The card has been set to a valid card;
This coding can also be used for other cards
|
The programmed state, no operation, the controller exits the programming state
|
In programming mode, if 20 within seconds, without any programming instructions, the system exits automatically programmed into the normal working state.
|